Inquiry
Form loading...

China Suppliers Factory Stainless Steel Vertical Storage Tank for Material Storage

Introducing our high-quality stainless steel vertical storage tank, a reliable solution for various storage needs. This robust tank, designed for optimal efficiency, stands tall with a tapered bottom, ensuring stability and effective liquid storage. As a leading manufacturer and supplier in China, our factory produces durable vertical tanks that meet industry standards. Choose our stainless steel vertical storage tank for a dependable storage option that enhances your operational capabilities.

Overview

1. Use

Vertical stainless steel storage tank is a kind of storage equipment, which has the characteristics of small floor area, easy installation, flexible and convenient operation.

2. Classification

According to its structure can be divided into single layer and double layer two types. The single layer type can be divided into two categories: cylinder type and elliptical type. According to its structural characteristics, the double-layer storage tank can be divided into the whole type and the assembly type, which can be divided into a variety of types according to different combination methods.

3. Main Technical Parameters
(1) Operating temperature range: -45°C~100°C
(2) Pressure range: 0mpa~10mpa
(3) Volume specifications: 1m³ to 1000m³
(4) Overall dimensions: 250mm × 500mm × 1500mm
(5) Weight details: Below 100 tons is 20t, 100-300T is 25t, 300-500kn is 40t, 500-1000kn is 50t, 1000-2000kg is 80 t, and 2000kg is 120 t.
4. Design Points
(1) Determine reasonable parameters and design calculation program; (2) Select the appropriate material; (3) Select a reasonable connection method.

Second, Structural Design

1. Foundation Requirements
  • The plane shape of the foundation should not cause distortion and damage to the building during transportation.
  • The foundation shall be closely integrated with the main project without detachment.
  • The foundation surface should be smooth and solid and have a certain bearing capacity.
  • The elevation of the foundation shall meet the requirements of the drawing and facilitate the leveling treatment during construction.
  • The bearing capacity of the foundation should be checked and calculated according to relevant codes.
2. Support System
  • The design principle of the support is to meet the strength requirements and consider the stability and durability of the structure.
  • For the container, multi-stage rubber vibration cushion or spring shock absorber can be used to reduce the noise and impact caused by the vibration transfer to the box.
  • For pipelines with displacement requirements, a guide device can be set.
  • The supporting system should be composed of elastic coupling parts such as welded ball hinge frame or cylindrical pin shaft.
3. Top Cover
  • The structure of the top cover mainly has two forms of spherical head and flat head.
  • The advantage of the spherical head is that the sealing performance is good.
  • The plate head is suitable for medium and low pressure large-capacity liquid medium transportation.
  • Due to the thermal expansion and contraction characteristics of the liquid, the wall thickness of the circular spherical container is thicker than that of the square plate.

Frequently Asked Questions (FAQ)

What are the main characteristics and uses of vertical stainless steel storage tanks?
Vertical stainless steel storage tanks are storage equipment designed for space efficiency and convenience. They feature a small floor area footprint, easy installation, and flexible, convenient operation.
How are these storage tanks classified structurally?
They are categorized into single-layer and double-layer types. Single-layer tanks include cylinder and elliptical types. Double-layer tanks include whole and assembly types, which can be configured into various combinations based on setup methods.
What are the operating limits for temperature and pressure?
The storage tanks are engineered to operate within a temperature range of -45°C to 100°C and can withstand pressure ranges from 0mpa up to 10mpa.
What are the critical aspects to consider during the design phase?
Key design parameters include establishing a reasonable design calculation program, selecting the most appropriate materials, and choosing a secure and logical connection method for the components.
What structural requirements must the tank foundation meet?
The foundation must prevent distortion or damage during transit, integrate seamlessly with the main project, provide a smooth and solid surface with verified bearing capacity, and align with design elevation drawings.
How do spherical head and flat head top covers differ?
Spherical heads offer superior sealing performance. Flat heads are preferred for medium and low-pressure, large-capacity liquid transport. Due to thermal expansion characteristics, circular spherical containers generally require thicker walls than square counterparts.